Test 1: What a Full Hysteresisgraph Loop Tells You About a Magnet Grade
A grade stamp such as N52 or SM2Co17-32 is a promise about three numbers: remanence, intrinsic coercivity and maximum energy product. A routine flux reading confirms the first one only. A hysteresisgraph, by contrast, drives the sample through saturation, pulls it back through the origin and traces the entire second quadrant, so the curve itself — not the label — becomes the evidence.
From one sweep the lab now records:
- Remanence (Br) — the flux density the magnet holds after saturation, measured in tesla.
- Intrinsic coercivity (Hcj) — the opposing field needed to bring the magnetization to zero, in kA/m.
- Maximum energy product (BH)max — the peak of the B×H product, the classic measure of stored magnetic energy.
- Squareness and recoil permeability — how flat the knee is, and how the curve behaves when the operating point shifts along minor loops.
Those last two items separate a datasheet magnet from a design magnet. Two parts can share identical Br and Hcj yet behave very differently under a demagnetizing load, because the shape of their demagnetization quadrant is not the same. The full loop captures that difference in a single sweep, and the lab can now run it the same day a sample comes off the finishing line.
Test 2: Hot Curves and Cold Starts — Reading Temperature Behavior
Magnets do not live at 20 °C. A motor housing may sit at 150 °C, a downhole tool hotter still, and a cryogenic valve far colder. The lab’s temperature chamber lets the hysteresisgraph pull a full curve at the temperature the part will actually see, from −40 °C to 350 °C, instead of extrapolating from a room-temperature certificate.
Two families of numbers come out of the hot runs. The reversible coefficients — how much Br and Hcj drift per degree — let engineers derate a design with real slopes rather than catalogue averages. The irreversible loss figure answers a harsher question: after the magnet is heated, held, and cooled back down, how much of its flux is gone for good?
Diffusion-processed low-Dy grades, the family our grain-boundary diffusion line produces, are specified precisely because they keep that permanent loss small at elevated temperature, and the in-house hysteresisgraph now verifies the claim lot by lot instead of trusting the incoming material certificate. The same rig characterizes our high-temperature Sm2Co17 series at its rated 350 °C ceiling, where NdFeB would already have given up most of its coercivity.
Test 3: Knee Point and Irreversible Loss — Will the Magnet Stay Magnetized?
A design fails in the field not when a magnet is weak, but when its operating point falls past the knee of the curve and the magnet partially self-demagnetizes. The knee is the region of the second quadrant where the slope steepens and small increases in opposing field cause disproportionate drops in flux.
The new lab quantifies the knee directly. The hysteresisgraph traces minor loops from the saturation point down to a defined demagnetizing field, then back up, and measures how much flux recovers and how much does not. From that sweep the engineer gets a load-line margin: the distance between the worst-case operating point in the assembly and the point where permanent loss begins.
This matters most for magnets in magnetic circuits with long air gaps, for motors under armature reaction, and for any assembly that sees field-weakening currents. A high Hcj number alone does not guarantee stability; a grade with a soft knee can lose five to ten percent of its flux in a single heat-and-demagnetize event and never recover it. The curve shows that risk before shipment, not after warranty.
Test 4: Batch Consistency and Traceability — From One Sample to Every Lot
Capability on a sample is marketing; capability on every lot is engineering. The second system in the lab — the pulsed hysteresisgraph — exists for throughput. It saturates the sample with a capacitor bank and reconstructs the demagnetization curve in milliseconds, which makes it practical to run statistical checks across a production batch rather than a single guarded specimen.
Every curve now carries a measurement record: instrument serial, calibration certificate against traceable standards, sample preparation notes including end-face correction for the aspect ratio used, and the lot number it belongs to. That paper trail is what buyers have come to expect from digital product passports and aerospace qualification files — the magnet world is converging on evidence, and an internal lab with traceable calibration is the fastest way to contribute to it.
For buyers, the practical effect is simple: a dispute over performance is settled with overlay plots of the actual delivered lots, not arguments about what the grade “should” do.
Four Costly Myths the New Lab Kills in One Afternoon
Years of outsourced testing taught the team which buyer assumptions collapse the moment a real curve appears. The table below maps each measurement the hysteresisgraph lab performs to the claim it proves and the myth it ends.
| Measurement | What It Proves | Costly Myth It Kills |
|---|---|---|
| Full B-H loop at 20 °C | Br, Hcj, (BH)max and quadrant shape from one sweep | The grade stamp alone guarantees performance |
| Curves from −40 °C to 350 °C | Real drift slopes and permanent loss at operating heat | Room-temperature datasheet values hold in a hot motor |
| Minor-loop knee trace | Load-line margin before irreversible demagnetization | High coercivity by itself ensures stability |
| Lot-overlay curves with calibration record | Batch-to-batch consistency on a traceable chain | One golden sample certifies the whole order |
Which system should a buyer ask for — electromagnetic or pulsed? — Electromagnetic for development, certification and any curve that must be beyond argument; pulsed for routine lot verification, where speed matters more than the last fraction of a percent.
Does every shipment come with a full hysteresisgraph curve? — No. Every lot gets a flux-gate check against its specification window, and curve traces are drawn on a sampling plan or whenever the application puts the operating point near the knee. Full curves for every lot are reserved for safety-critical programs.
Is In-House Hysteresisgraph Data Right for Your Program? Answer These 3 Questions
Ordering magnets against curve evidence changes what you ask a supplier. Three questions decide whether the new lab earns its place in your program:
- At which temperature do you want the curve? A 20 °C trace flatters every grade. If your assembly runs hot, require the hysteresisgraph sweep at the operating temperature and read the irreversible loss, not the room-temperature headline.
- What does the measurement chain look like? Ask which instrument drew the curve, when it was last calibrated against traceable standards, and how the sample was prepared. End-face correction and aspect ratio move the numbers more than most buyers expect.
- Does the report show the demagnetizing quadrant? A certificate listing only Br, Hcj and (BH)max hides the knee. Insist on the full second-quadrant plot so your load line can be checked against real delivered data.
To Summary
The hysteresisgraph lab moves magnet verification from a promise on a label to a curve in a file. Same-day traces replace weeks of outsourcing, temperature sweeps replace extrapolation, knee measurements replace guesswork, and lot overlays replace the golden-sample myth. For buyers, the change is quiet but real: the evidence arriving with each shipment now describes the magnets you actually received, not the grade they were nominally ordered under.