Frame 1: What a Flux Viewer Actually Shows
A flux viewer is not a camera and not a gaussmeter with one reading — it is both, disciplined into a grid. The probe array traverses the pole face at a fixed lift distance, recording field strength and direction at every point, and the software paints the result: bright bands where flux crosses the face, dark lines where it hides, sharp boundaries where one pole hands off to the next.
From that single image a reader can verify what no dimensional gauge can: that the pole count is right, that every pole carries its specified amplitude, that the pattern is centered on the geometry rather than drifting a fraction of a pitch, and that polarity runs the direction the drawing claims. The bench stores each map against the lot number, so the golden sample’s map becomes the reference every future shipment is measured against — the same file-to-file comparison discipline the automotive program is now built on.
Frame 2: The Defects Only Flux Can See
The value of a flux viewer is the failure modes invisible to everything else. A magnet can be perfectly ground, perfectly coated and perfectly wrong: a fixture coil with a shorted turn prints one weak pole on every ring in the lot; a worn pole shoe shifts the pattern half a pitch; a brittle arc that chipped in transit lost its edge flux. None of these move a caliper. Every one of them moves a sensor reading.
The second class of catches is subtler and more expensive: partial demagnetization. A rotor that took a demagnetizing field during a handling accident arrives with dimensions intact and performance gutted — the knee crossed, the flux redistributed, the waveform flattened. The flux viewer sees the shadow of it immediately, because a demagnetized region reads dark in a place that should be bright. Overmolded assemblies add one more case the old sampling route could never cover: the carrier with the magnet missing, seated upside down, or replaced between cavities. The map finds it in seconds per frame.
Frame 3: One Hundred Percent, Every Lot
Sampling was an economic decision made when inspection was slow. An automated flux viewer bench changes the economics: the part is mapped in the same handling pass that moves it from the magnetizer to the packing station, with no operator judgment in the loop and a pass/fail verdict against the stored golden map returned before the carton closes.
Rejected parts divert by defect signature — weak pole, polarity flip, pattern shift, demagnetized zone — and each signature points back at a named process: the fixture, the coil, the handling step. That is the quiet upgrade buyers should read from this news: not just that bad parts are caught, but that the reason code arrives while the lot is still in the building. The flux viewer turns inspection from a gate into feedback, the same logic the dimensional line applies to geometry.
Flux Viewer Versus the Old Sampling Route
The two inspection philosophies answer the same four questions very differently:
| Question | Sampled Check | Full-Map Bench |
|---|---|---|
| One weak pole in an unsampled ring | Ships; found at the customer’s sensor test | Caught before the carton closes |
| Polarity flip in half a lot | Detected only if the sample drew the flipped side | Every part verified against the golden map |
| Partial demagnetization in transit | Invisible until the assembly underperforms | Dark zone flagged at receiving re-map |
| Assembly with a missing magnet | Statistically untouched by a one-per-lot check | Empty pocket reads as a defect signature |
Does the flux viewer measure the grade — Br, coercivity, energy product? — No, and it should not try. The bench images the surface field of the finished part; the intrinsic numbers belong to the hysteresisgraph lab, where cut-down witness samples answer grade questions. Map plus curve is the complete story, and both now happen under one roof.
Which parts get mapped one hundred percent by default? — Magnetized encoder rings, multipole rotors, assemblies with embedded magnets and any order whose specification names per-pole amplitude. Simple single-pole discs stay on the dimensional line’s routine checks unless the buyer asks otherwise.
Should Your Order Require Full Flux Viewer Mapping? Answer These 3 Questions
- Does a sensor read your magnet? If a Hall element, reed switch or encoder head interprets the field, then per-pole amplitude and pattern position are functional dimensions — and functional dimensions deserve full inspection rather than a lottery.
- Would one weak pole stop your line? A defect that fails one assembly out of a thousand is cheap; one that stops the line to hunt its source is not. Full mapping pays the moment a single escaped part costs more than the inspection of the whole lot.
- Can you use the maps afterward? The real compounding value is comparison: a customer who keeps each lot’s golden map can re-map returned parts at receiving and see exactly what transport or installation did to the flux. If your team will use that file, the flux viewer keeps working long after the shipment is accepted.
To Summary
The new bench makes the invisible half of magnet quality visible on every part: the flux viewer images what the grinder cannot guarantee and the caliper cannot see, and it does so at the speed of the line rather than the speed of a sample plan. Weak poles, flipped polarity, demagnetized shadows and empty magnet pockets now end their journey at our dock instead of the customer’s sensor. Three frames, one map per part — and the old mistakes of sampling quietly retired with them.
Pre-sales Agent